Copper-deposited wire ion-selective electrode for the determination of copper(II)
Samo za registrovane korisnike
1987
Članak u časopisu (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentuApstrakt
A wire ion-selective electrode was made by sulphiding electrolytic copper previously deposited on commercial copper wire. Sulphidation was carried out by means of gaseous hydrogen sulphide at an increased temperature. The electrode not only possesses good properties but it can also be coupled with an SCE to determine copper in potentiometric titrations with different complexing agents in both aqueous and non-aqueous solutions.
Ključne reči:
Copper wire ion-selective electrode / Copper(I) sulphide monolayer / Copper(II) determinationIzvor:
The Analyst, 1987, 112, 4, 539-542Institucija/grupa
Poljoprivredni fakultetTY - JOUR AU - Vučurović, B.D. AU - Rajković, Miloš PY - 1987 UR - http://aspace.agrif.bg.ac.rs/handle/123456789/64 AB - A wire ion-selective electrode was made by sulphiding electrolytic copper previously deposited on commercial copper wire. Sulphidation was carried out by means of gaseous hydrogen sulphide at an increased temperature. The electrode not only possesses good properties but it can also be coupled with an SCE to determine copper in potentiometric titrations with different complexing agents in both aqueous and non-aqueous solutions. T2 - The Analyst T1 - Copper-deposited wire ion-selective electrode for the determination of copper(II) EP - 542 IS - 4 SP - 539 VL - 112 DO - 10.1039/AN9871200539 ER -
@article{ author = "Vučurović, B.D. and Rajković, Miloš", year = "1987", abstract = "A wire ion-selective electrode was made by sulphiding electrolytic copper previously deposited on commercial copper wire. Sulphidation was carried out by means of gaseous hydrogen sulphide at an increased temperature. The electrode not only possesses good properties but it can also be coupled with an SCE to determine copper in potentiometric titrations with different complexing agents in both aqueous and non-aqueous solutions.", journal = "The Analyst", title = "Copper-deposited wire ion-selective electrode for the determination of copper(II)", pages = "542-539", number = "4", volume = "112", doi = "10.1039/AN9871200539" }
Vučurović, B.D.,& Rajković, M.. (1987). Copper-deposited wire ion-selective electrode for the determination of copper(II). in The Analyst, 112(4), 539-542. https://doi.org/10.1039/AN9871200539
Vučurović B, Rajković M. Copper-deposited wire ion-selective electrode for the determination of copper(II). in The Analyst. 1987;112(4):539-542. doi:10.1039/AN9871200539 .
Vučurović, B.D., Rajković, Miloš, "Copper-deposited wire ion-selective electrode for the determination of copper(II)" in The Analyst, 112, no. 4 (1987):539-542, https://doi.org/10.1039/AN9871200539 . .
Related items
Showing items related by title, author, creator and subject.
-
Complexometric determination: Part II: Complexometric determination of Cu2+-ions / Kompleksometrijska određivanja - deo 2 - kompleksometrijsko određivanje Cu2+-jona
Rajković, Miloš (Savez hemijskih inženjera, Beograd, 2002) -
Flowability of electrolytic copper powder
Pavlović, MG; Popov, Konstantin I.; Krstić, Snežana B.; Pavlović, Ljubica; Ivanović, Evica (6th Conference of the Yugoslav Materials Research Society, YUCOMAT VI: Current Research in Advanced Materials and Processes, 2005) -
The effect of reversing current on the properties of copper and electrolytic copper powder II. The apparent density and flowability of powders
Popov, Konstantin I.; Pavlović, MG; Pavlović, Ljubica; Maksimović, VM; Ivanović, Evica (Trans Tech Publications Ltd, Durnten-Zurich, 2004)