Tosković, Dragan V.

Link to this page

Authority KeyName Variants
e1928c74-5b31-4c4c-84b5-4405ee79cbda
  • Tosković, Dragan V. (2)
Projects

Author's Bibliography

Lead and silver extraction from waste cake from hydrometallurgical zinc production

Stanojević, Dušan D.; Rajković, Miloš; Tosković, Dragan V.; Tomić, Milana A.

(Srpsko hemijsko društvo, Beograd, 2008)

TY  - JOUR
AU  - Stanojević, Dušan D.
AU  - Rajković, Miloš
AU  - Tosković, Dragan V.
AU  - Tomić, Milana A.
PY  - 2008
UR  - http://aspace.agrif.bg.ac.rs/handle/123456789/1809
AB  - This paper presents the experimental results of the extraction of lead and silver from a lead-silver waste cake obtained in the process of hydrometallurgical zinc production. While controlling the pH value, the lead-silver cake was leached at a temperature close to boiling point in different concentrations of aqueous calcium chloride solutions. The experiments were performed applying different ratios between the mass of cake and the volume of the leaching agent under different durations of the process. It was concluded that at the optimal process parameters (pH 2.0-2.5; CaCl2 concentration, 3.6 mol dm(-3); temperature, 95 degrees C; solid/liquid ratio, 1:5), the leaching efficiency of lead and silver could reach the approximate value of 94 %. Applying the same optimal process parameters, the method was applied to the leaching of a lead-silver cake in a magnesium chloride solution, but with significantly lower efficiencies. The results show that leaching of lead and silver in a calcium chloride solution could be a prospective method for increasing the recovery of lead and silver during hydrometallurgical zinc production.
PB  - Srpsko hemijsko društvo, Beograd
T2  - JOURNAL OF THE SERBIAN CHEMICAL SOCIETY
T1  - Lead and silver extraction from waste cake from hydrometallurgical zinc production
EP  - 593
IS  - 5
SP  - 585
VL  - 73
DO  - 10.2298/JSC0805585S
ER  - 
@article{
author = "Stanojević, Dušan D. and Rajković, Miloš and Tosković, Dragan V. and Tomić, Milana A.",
year = "2008",
abstract = "This paper presents the experimental results of the extraction of lead and silver from a lead-silver waste cake obtained in the process of hydrometallurgical zinc production. While controlling the pH value, the lead-silver cake was leached at a temperature close to boiling point in different concentrations of aqueous calcium chloride solutions. The experiments were performed applying different ratios between the mass of cake and the volume of the leaching agent under different durations of the process. It was concluded that at the optimal process parameters (pH 2.0-2.5; CaCl2 concentration, 3.6 mol dm(-3); temperature, 95 degrees C; solid/liquid ratio, 1:5), the leaching efficiency of lead and silver could reach the approximate value of 94 %. Applying the same optimal process parameters, the method was applied to the leaching of a lead-silver cake in a magnesium chloride solution, but with significantly lower efficiencies. The results show that leaching of lead and silver in a calcium chloride solution could be a prospective method for increasing the recovery of lead and silver during hydrometallurgical zinc production.",
publisher = "Srpsko hemijsko društvo, Beograd",
journal = "JOURNAL OF THE SERBIAN CHEMICAL SOCIETY",
title = "Lead and silver extraction from waste cake from hydrometallurgical zinc production",
pages = "593-585",
number = "5",
volume = "73",
doi = "10.2298/JSC0805585S"
}
Stanojević, D. D., Rajković, M., Tosković, D. V.,& Tomić, M. A.. (2008). Lead and silver extraction from waste cake from hydrometallurgical zinc production. in JOURNAL OF THE SERBIAN CHEMICAL SOCIETY
Srpsko hemijsko društvo, Beograd., 73(5), 585-593.
https://doi.org/10.2298/JSC0805585S
Stanojević DD, Rajković M, Tosković DV, Tomić MA. Lead and silver extraction from waste cake from hydrometallurgical zinc production. in JOURNAL OF THE SERBIAN CHEMICAL SOCIETY. 2008;73(5):585-593.
doi:10.2298/JSC0805585S .
Stanojević, Dušan D., Rajković, Miloš, Tosković, Dragan V., Tomić, Milana A., "Lead and silver extraction from waste cake from hydrometallurgical zinc production" in JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 73, no. 5 (2008):585-593,
https://doi.org/10.2298/JSC0805585S . .
3
1

Identification of metals (heavy and radioactive) in drinking water by an indirect analysis method based on scale tests

Rajković, Miloš; Lačnjevac, Časlav; Ralević, Nebojša; Stojanović, Mirjana D.; Tosković, Dragan V.; Pantelić, Gordana K.; Ristić, Nikola; Jovanić, Sasa

(MDPI, BASEL, 2008)

TY  - JOUR
AU  - Rajković, Miloš
AU  - Lačnjevac, Časlav
AU  - Ralević, Nebojša
AU  - Stojanović, Mirjana D.
AU  - Tosković, Dragan V.
AU  - Pantelić, Gordana K.
AU  - Ristić, Nikola
AU  - Jovanić, Sasa
PY  - 2008
UR  - http://aspace.agrif.bg.ac.rs/handle/123456789/1810
AB  - The analysis of water quality, regarding the content of metals, especially heavy and radioactive ones, has been carried out in an indirect way, by testing scale formed in a hot-water heater, using water from the water-supply network of the city of Belgrade - the district of New Belgrade. The determination of the composition and the structure of the scale has resulted in its complete identification, and its crystallochemical formula has been defined. It has unequivocally been established that the obtained results are within the tolerance boundary with the results acquired by a conventional analysis of water, when it is a matter of very low concentrations. The presence of radioactive elements of uranium and strontium in a scale sample has been found and the way of their penetrating its composition and structure has been explained. Applying the fractional extraction method, uranium has been established to be of an anthropogenic origin.
PB  - MDPI, BASEL
T2  - Sensors
T1  - Identification of metals (heavy and radioactive) in drinking water by an indirect analysis method based on scale tests
EP  - 2207
IS  - 4
SP  - 2188
VL  - 8
DO  - 10.3390/s8042188
ER  - 
@article{
author = "Rajković, Miloš and Lačnjevac, Časlav and Ralević, Nebojša and Stojanović, Mirjana D. and Tosković, Dragan V. and Pantelić, Gordana K. and Ristić, Nikola and Jovanić, Sasa",
year = "2008",
abstract = "The analysis of water quality, regarding the content of metals, especially heavy and radioactive ones, has been carried out in an indirect way, by testing scale formed in a hot-water heater, using water from the water-supply network of the city of Belgrade - the district of New Belgrade. The determination of the composition and the structure of the scale has resulted in its complete identification, and its crystallochemical formula has been defined. It has unequivocally been established that the obtained results are within the tolerance boundary with the results acquired by a conventional analysis of water, when it is a matter of very low concentrations. The presence of radioactive elements of uranium and strontium in a scale sample has been found and the way of their penetrating its composition and structure has been explained. Applying the fractional extraction method, uranium has been established to be of an anthropogenic origin.",
publisher = "MDPI, BASEL",
journal = "Sensors",
title = "Identification of metals (heavy and radioactive) in drinking water by an indirect analysis method based on scale tests",
pages = "2207-2188",
number = "4",
volume = "8",
doi = "10.3390/s8042188"
}
Rajković, M., Lačnjevac, Č., Ralević, N., Stojanović, M. D., Tosković, D. V., Pantelić, G. K., Ristić, N.,& Jovanić, S.. (2008). Identification of metals (heavy and radioactive) in drinking water by an indirect analysis method based on scale tests. in Sensors
MDPI, BASEL., 8(4), 2188-2207.
https://doi.org/10.3390/s8042188
Rajković M, Lačnjevac Č, Ralević N, Stojanović MD, Tosković DV, Pantelić GK, Ristić N, Jovanić S. Identification of metals (heavy and radioactive) in drinking water by an indirect analysis method based on scale tests. in Sensors. 2008;8(4):2188-2207.
doi:10.3390/s8042188 .
Rajković, Miloš, Lačnjevac, Časlav, Ralević, Nebojša, Stojanović, Mirjana D., Tosković, Dragan V., Pantelić, Gordana K., Ristić, Nikola, Jovanić, Sasa, "Identification of metals (heavy and radioactive) in drinking water by an indirect analysis method based on scale tests" in Sensors, 8, no. 4 (2008):2188-2207,
https://doi.org/10.3390/s8042188 . .
13
11
19