Measurement of the DC Stark shift for visible Ne I lines and electric field distribution in the cathode sheath of an abnormal glow discharge
Само за регистроване кориснике
2017
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
We present the results of an experimental study of the DC Stark shift for seven visible NeI
lines in the plane cathode sheath region of an abnormal glow discharge operated in neon with
a small admixture of hydrogen. The electric field (up to 13.4 kV cm−1) in the cathode sheath
region is measured from the π-polarized profile of the H alpha line of hydrogen using the
Stark polarization spectroscopy technique. Within the realized range of the electric field, the
NeI lines exhibit a quadratic Stark effect. The values of coefficients, correlating Stark shift and
electric field strength, were determined, enabling their future use for unknown electric field
strength measurements. Among the studied lines, so far only the Stark effect analysis of the
NeI 511.367 nm line has been reported, in which case our results are in good agreement with
the best fit formula proposed by Jäger and Windholz (1984 Phys. Scr. 29 344) for one out of
three Stark components detected under our experimental... conditions.
Кључне речи:
glow discharge / optical emission spectroscopy / Stark effect / hydrogen and neon line shapes and shifts / electric field measurementsИзвор:
Journal of Physics D: Applied Physics, 2017, 50Издавач:
- IOP Publishing
Финансирање / пројекти:
- Спектроскопска дијагностика нискотемпературне плазме и ганих пражњења: облици спектралних линија и интеракција са површинама (RS-MESTD-Basic Research (BR or ON)-171014)
- Суперпроводност, магнетизам и флуктуационе појаве (RS-MESTD-Basic Research (BR or ON)-171027)
Институција/група
Poljoprivredni fakultetTY - JOUR AU - Ivanović, N. V. AU - Šišović, N. M. AU - Spasojević, Dj. AU - Konjević, N. PY - 2017 UR - http://aspace.agrif.bg.ac.rs/handle/123456789/6918 AB - We present the results of an experimental study of the DC Stark shift for seven visible NeI lines in the plane cathode sheath region of an abnormal glow discharge operated in neon with a small admixture of hydrogen. The electric field (up to 13.4 kV cm−1) in the cathode sheath region is measured from the π-polarized profile of the H alpha line of hydrogen using the Stark polarization spectroscopy technique. Within the realized range of the electric field, the NeI lines exhibit a quadratic Stark effect. The values of coefficients, correlating Stark shift and electric field strength, were determined, enabling their future use for unknown electric field strength measurements. Among the studied lines, so far only the Stark effect analysis of the NeI 511.367 nm line has been reported, in which case our results are in good agreement with the best fit formula proposed by Jäger and Windholz (1984 Phys. Scr. 29 344) for one out of three Stark components detected under our experimental conditions. PB - IOP Publishing T2 - Journal of Physics D: Applied Physics T1 - Measurement of the DC Stark shift for visible Ne I lines and electric field distribution in the cathode sheath of an abnormal glow discharge IS - 50 DO - 10.1088/1361-6463/aa5c1f ER -
@article{ author = "Ivanović, N. V. and Šišović, N. M. and Spasojević, Dj. and Konjević, N.", year = "2017", abstract = "We present the results of an experimental study of the DC Stark shift for seven visible NeI lines in the plane cathode sheath region of an abnormal glow discharge operated in neon with a small admixture of hydrogen. The electric field (up to 13.4 kV cm−1) in the cathode sheath region is measured from the π-polarized profile of the H alpha line of hydrogen using the Stark polarization spectroscopy technique. Within the realized range of the electric field, the NeI lines exhibit a quadratic Stark effect. The values of coefficients, correlating Stark shift and electric field strength, were determined, enabling their future use for unknown electric field strength measurements. Among the studied lines, so far only the Stark effect analysis of the NeI 511.367 nm line has been reported, in which case our results are in good agreement with the best fit formula proposed by Jäger and Windholz (1984 Phys. Scr. 29 344) for one out of three Stark components detected under our experimental conditions.", publisher = "IOP Publishing", journal = "Journal of Physics D: Applied Physics", title = "Measurement of the DC Stark shift for visible Ne I lines and electric field distribution in the cathode sheath of an abnormal glow discharge", number = "50", doi = "10.1088/1361-6463/aa5c1f" }
Ivanović, N. V., Šišović, N. M., Spasojević, Dj.,& Konjević, N.. (2017). Measurement of the DC Stark shift for visible Ne I lines and electric field distribution in the cathode sheath of an abnormal glow discharge. in Journal of Physics D: Applied Physics IOP Publishing.(50). https://doi.org/10.1088/1361-6463/aa5c1f
Ivanović NV, Šišović NM, Spasojević D, Konjević N. Measurement of the DC Stark shift for visible Ne I lines and electric field distribution in the cathode sheath of an abnormal glow discharge. in Journal of Physics D: Applied Physics. 2017;(50). doi:10.1088/1361-6463/aa5c1f .
Ivanović, N. V., Šišović, N. M., Spasojević, Dj., Konjević, N., "Measurement of the DC Stark shift for visible Ne I lines and electric field distribution in the cathode sheath of an abnormal glow discharge" in Journal of Physics D: Applied Physics, no. 50 (2017), https://doi.org/10.1088/1361-6463/aa5c1f . .