Copper-deposited wire ion-selective electrode for the determination of copper(II)
Само за регистроване кориснике
1987
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
A wire ion-selective electrode was made by sulphiding electrolytic copper previously deposited on commercial copper wire. Sulphidation was carried out by means of gaseous hydrogen sulphide at an increased temperature. The electrode not only possesses good properties but it can also be coupled with an SCE to determine copper in potentiometric titrations with different complexing agents in both aqueous and non-aqueous solutions.
Кључне речи:
Copper wire ion-selective electrode / Copper(I) sulphide monolayer / Copper(II) determinationИзвор:
The Analyst, 1987, 112, 4, 539-542Институција/група
Poljoprivredni fakultetTY - JOUR AU - Vučurović, B.D. AU - Rajković, Miloš PY - 1987 UR - http://aspace.agrif.bg.ac.rs/handle/123456789/64 AB - A wire ion-selective electrode was made by sulphiding electrolytic copper previously deposited on commercial copper wire. Sulphidation was carried out by means of gaseous hydrogen sulphide at an increased temperature. The electrode not only possesses good properties but it can also be coupled with an SCE to determine copper in potentiometric titrations with different complexing agents in both aqueous and non-aqueous solutions. T2 - The Analyst T1 - Copper-deposited wire ion-selective electrode for the determination of copper(II) EP - 542 IS - 4 SP - 539 VL - 112 DO - 10.1039/AN9871200539 ER -
@article{ author = "Vučurović, B.D. and Rajković, Miloš", year = "1987", abstract = "A wire ion-selective electrode was made by sulphiding electrolytic copper previously deposited on commercial copper wire. Sulphidation was carried out by means of gaseous hydrogen sulphide at an increased temperature. The electrode not only possesses good properties but it can also be coupled with an SCE to determine copper in potentiometric titrations with different complexing agents in both aqueous and non-aqueous solutions.", journal = "The Analyst", title = "Copper-deposited wire ion-selective electrode for the determination of copper(II)", pages = "542-539", number = "4", volume = "112", doi = "10.1039/AN9871200539" }
Vučurović, B.D.,& Rajković, M.. (1987). Copper-deposited wire ion-selective electrode for the determination of copper(II). in The Analyst, 112(4), 539-542. https://doi.org/10.1039/AN9871200539
Vučurović B, Rajković M. Copper-deposited wire ion-selective electrode for the determination of copper(II). in The Analyst. 1987;112(4):539-542. doi:10.1039/AN9871200539 .
Vučurović, B.D., Rajković, Miloš, "Copper-deposited wire ion-selective electrode for the determination of copper(II)" in The Analyst, 112, no. 4 (1987):539-542, https://doi.org/10.1039/AN9871200539 . .
Related items
Showing items related by title, author, creator and subject.
-
Complexometric determination: Part II: Complexometric determination of Cu2+-ions / Kompleksometrijska određivanja - deo 2 - kompleksometrijsko određivanje Cu2+-jona
Rajković, Miloš (Savez hemijskih inženjera, Beograd, 2002) -
Application of a copper-selective electrode coated wire type to the determination of copper(II) by potentiometric titrations with ethylenediamine in aqueous and nonaqueous solutions / Primena bakar-selektivne elektrode tipa prekrivena žica za određivanje bakra(II) potenciometrijskom titracijom sa etilendiaminom u vodenim i nevodenim rastvorima
Rajković, Miloš; Vučurović, Borislava D.; Tošković, Dragan (Univerzitet u Novom Sadu - Tehnološki fakultet, Novi Sad, 2000) -
Flowability of electrolytic copper powder
Pavlović, MG; Popov, Konstantin I.; Krstić, Snežana B.; Pavlović, Ljubica; Ivanović, Evica (6th Conference of the Yugoslav Materials Research Society, YUCOMAT VI: Current Research in Advanced Materials and Processes, 2005)